Anesthesia Machine with Ventilator (TR-560B2)

Anesthesia Machine with Ventilator (TR-560B2)

ventilator anesthesia
INQUIRY PRECISE INQUIRY
Description

Basic Info
  • Model NO.: TR-560B2
  • Certification: CE
  • Anesthesia: All-Close, Semi-Close, Semi-Open
  • Transport Package: 1 Set/Carton
  • Origin: Jiangsu, China
  • Type: Anaesthesia Machine
  • Source: O2, N2o
  • Trademark: Neutral English
  • Specification: CE&ISO
  • HS Code: 90189070
Product Description
TR-560B2 Anesthesia Machine

TR-560B2 Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.
1. The Ventilator adopts microcomputer control with high-definition 5.7" LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
2. The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
3. Reliable pneumatic transmission system.
4. Economic and proper configuration of technologies, optional as required by the Customer.
5. Modularized design and upgrading. Upgrading is available as required by the Customer.
 
Part of Anesthesia Machine
-Main body: High-strength engineering plastic rack, light, beautiful and corrosion resistant
-Scope of application: adult, child
-Gas source:                  O2: 0.27~0.55MPa  N2O: 0.27~0.55MPa
-Flow meter:                    O2: 0.1~10L/min      N2O: 0.1~10L/min
-O2, N2O linkage and N2O Stopper
 When using nitrous oxide, oxygen concentration>25%;
 When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
-Flow rate of rapid oxygen supply:  25~75L/min
-Low oxygen pressure alarm:     There will be sound alarm when the oxygen                   pressure < 0.2MPa
-Vaporizer:                   it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
-Respiratory circuit:             working mode: all-close, semi-close, semi-open
                                                               releasing pressure: 0.5~7 kPa
-Respiratory bellows:           bellows for adults, bellows for children
                                                   tidal volume range:0~1,500 ml
 
Part of Ventilator
-Display mode:                High-definition 5.7" LCD screen display
-Ventilation mode:             IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH
-Ventilation parameters:         
Tidal volume          50
~1500ml
Rate                        2~99bmp
SIMV rate               2~20bpm
I:E                            2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP                     0~2.0 kPa
Pressure range         1.0~6.0 kPa
SIGH    1.5 times the inspiratory time
-Parameters for ventilation monitoring:  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
-Monitoring of oxygen concentration:  (21%~100%)
-Security Alarm System
Oxygen Concentration alarm    upper limit setting range (50%~100%)
                              low limit setting range  (15%~50%)
Airway pressure alarm         upper limit setting range  1.0~6.0 kPa
                              low limit setting range   0.4~2.0 kPa
Per-minute ventilation volume alarm  upper limit setting range  3.0~30L/min
                                  low limit setting range   1.0~10L/min
Sustained high-pressure alarm     it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm             it will give sound and light alarm if there is no tidal volume input for 15 seconds

Anesthesia Machine with Ventilator (TR-560B2)